THERMOSTATIC HEAD WITH VALVE
By fitting the thermostatic head with wax sensor, coupled with a closing valve, the option is provided of regulating the skirting heating system in every room. This regulation system does not permit intervening from a single precise point, but requires manual intervention in each room. It does not automatically set day/night and holiday temperature. The RE thermostatic head and the RR valve are fitted directly on the THERMBORD skirting (see photo).
The required temperatures can be regulated by means of a revolving head fitted on the thermostat. The number is marked on the revolving head and corresponds to following temperature.
| CLOSED | 0 | |
| ANTIFREEZE | X | 8° C |
| POSITION | 1 | 10° C |
| " | 3 | 14° C |
| " | 5 | 18° C |
| " | 6 | 20° C |
| " | 7 | 22° C |
| " | 8 | 24° C |
The set position can vary by about 2 degrees with respect to the set temperature.

RE Thermostatic
head with wax sensor
RR Closing valve